IDS-50xx

From AcceedWiki
(Difference between revisions)
Jump to: navigation, search
m (IDS-50XX moved to IDS-50xx)
 
(2 intermediate revisions by one user not shown)
Line 1: Line 1:
IDS-50XX are serial device servers for either serial-over-ethernet and/or serial-over-WLAN communication (IDS-50XX-WG models). Several models (IDS-50X2) feature dual LAN ports for ethernet redundancy (recovery time <10ms). Also all models share redundant dual power inputs (12-48VDC). The supplied DS-Tools setup & administration software allows complete configuration of devices, and includes Wizard function for easy step-by-step setup of all connected devices.
+
IDS-50xx are serial device servers for either serial-over-ethernet and/or serial-over-WLAN communication (IDS-50xx-WG models). Several models (IDS-50x2) feature dual LAN ports for ethernet redundancy (recovery time <10ms). Also all models share redundant dual power inputs (12-48VDC). The supplied DS-Tools setup & administration software allows complete configuration of devices, and includes Wizard function for easy step-by-step setup of all connected devices.
  
 
== General hints ==
 
== General hints ==
* When connecting the modules for the first time with the host PC, make sure both are in the same subnet. The default IP of IDS-50XX is 192.168.10.2 - so the host PC should have for example 192.168.10.1 or any other IP in the 192.168.10 subnet. Otherwise, DS-Tools might not be able to connect to the device. You may change the device´s IP address via DS-Tools later.
 
  
== IDS-50XX-WG (WLAN models) hints ==
+
* When connecting the modules for the first time with the host PC, make sure both are in the same subnet. The default IP of IDS-50xx is 192.168.10.2 - so the host PC should have for example 192.168.10.1 or any other IP in the 192.168.10 subnet. Otherwise, DS-Tools might not be able to connect to the device. You may change the device´s IP address via DS-Tools later.
* If you want IDS-50XX-WG to connect to your host PC (or another IDS-50XX-WG in tunnel mode), make sure no ethernet cable is connected to IDS-50XX-WG´s LAN port. If IDS-50XX-WG is connected via LAN, it will automatically disable WLAN to avoid dual connection. So, WLAN will only work when there is no connection to a wire-based LAN available.
+
 
 +
== IDS-50xx-WG (WLAN models) hints ==
 +
 
 +
* If you want IDS-50xx-WG to connect to your host PC (or another IDS-50xx-WG in tunnel mode), make sure no ethernet cable is connected to IDS-50xx-WG´s LAN port. If IDS-50xx-WG is connected via LAN, it will automatically disable WLAN to avoid dual connection. So, WLAN will only work when there is no connection to a wire-based LAN available.
 
* The SSID of your WLAN should not contain a "space" - i.e., you may call it for example "IDS_WLAN", but "IDS WLAN" will not work.
 
* The SSID of your WLAN should not contain a "space" - i.e., you may call it for example "IDS_WLAN", but "IDS WLAN" will not work.
  
 
== IP Module In Serial Tunnel ==
 
== IP Module In Serial Tunnel ==
* In paired mode (or tunnel mode) you will need 2 IDS-50XX
+
 
 +
* In paired mode (or tunnel mode) you will need 2 IDS-50xx
 
* Choose either TCP (safer, recommended) or UDP (faster) mode
 
* Choose either TCP (safer, recommended) or UDP (faster) mode
 
* One module needs to work as "client" and the other as "server"
 
* One module needs to work as "client" and the other as "server"
 
* DS-Tools (included) allows easy tunnel mode setup via step-by-step Wizard
 
* DS-Tools (included) allows easy tunnel mode setup via step-by-step Wizard
* Tunnel mode works either via LAN or WLAN connection (IDS-50XX-WG models)
+
* Tunnel mode works either via LAN or WLAN connection (IDS-50xx-WG models)
  
  
[[Category:Produkt|IDS-50XX]]
+
[[Category:Produkt|IDS-50xx]]

Latest revision as of 14:58, 1 July 2010

IDS-50xx are serial device servers for either serial-over-ethernet and/or serial-over-WLAN communication (IDS-50xx-WG models). Several models (IDS-50x2) feature dual LAN ports for ethernet redundancy (recovery time <10ms). Also all models share redundant dual power inputs (12-48VDC). The supplied DS-Tools setup & administration software allows complete configuration of devices, and includes Wizard function for easy step-by-step setup of all connected devices.

[edit] General hints

  • When connecting the modules for the first time with the host PC, make sure both are in the same subnet. The default IP of IDS-50xx is 192.168.10.2 - so the host PC should have for example 192.168.10.1 or any other IP in the 192.168.10 subnet. Otherwise, DS-Tools might not be able to connect to the device. You may change the device´s IP address via DS-Tools later.

[edit] IDS-50xx-WG (WLAN models) hints

  • If you want IDS-50xx-WG to connect to your host PC (or another IDS-50xx-WG in tunnel mode), make sure no ethernet cable is connected to IDS-50xx-WG´s LAN port. If IDS-50xx-WG is connected via LAN, it will automatically disable WLAN to avoid dual connection. So, WLAN will only work when there is no connection to a wire-based LAN available.
  • The SSID of your WLAN should not contain a "space" - i.e., you may call it for example "IDS_WLAN", but "IDS WLAN" will not work.

[edit] IP Module In Serial Tunnel

  • In paired mode (or tunnel mode) you will need 2 IDS-50xx
  • Choose either TCP (safer, recommended) or UDP (faster) mode
  • One module needs to work as "client" and the other as "server"
  • DS-Tools (included) allows easy tunnel mode setup via step-by-step Wizard
  • Tunnel mode works either via LAN or WLAN connection (IDS-50xx-WG models)